home *** CD-ROM | disk | FTP | other *** search
EISA add-on card Configuration | 1994-06-21 | 10.5 KB | 366 lines |
- ;╔═════════════════════════════════════════════════════════════════╗
- ;║ ║
- ;║ Token ring Network 16/4 Adapter II ║
- ;║ Adapter Configuration File Version 1.00 ║
- ;║ ║
- ;╚═════════════════════════════════════════════════════════════════╝
-
- BOARD
- ID = "OEM5120"
- NAME = "Token ring Network 16/4 Adapter II"
- MFR = "OEM"
- CATEGORY = "NET"
- SLOT = ISA16
- LENGTH = 285
- AMPERAGE = 700
- SKIRT = NO
- READID = NO
- BUSMASTER = 1
- IOCHECK = INVALID
- DISABLE = UNSUPPORTED
-
- COMMENTS = "\nThe Token ring Network 16/4 Adapter II
- is designed for use in ISA and EISA bus computers.\n\n
- The EISA configuration utility will identify a conflict-
- free configuration of system resources and suggest
- switch settings for the adapter. Prior to exiting the
- utility, record the suggested switch settings, then exit
- and set switches manually on the adapter before continuing
- any Token ring 16/4 Adapter II operation.\n
- NOTE: To activate a change of the switch settings
- a power ON/OFF cycle must be executed"
-
-
- SWITCH(1) = 12
- NAME = "SW1 Configuration Switch"
- STYPE = DIP
- VERTICAL = YES
- REVERSE = YES
- LABEL = LOC(1-12) "1" "2" "3" "4" "5" "6" "7" "8" "9" "10" "11" "12"
- FACTORY = LOC(1-12) 111111111111
- COMMENTS = "\nSwitch Block SW1 is an 12-position configuration DIP-switch
- used to set the IO address / interrupt level / DMA channel /
- Ring Speed / Cable Type and to enable Remote Program Load.
- Three positions of SW1 (1-3) are used to set the ROM address /
- IO address and the remaining nine positions are used to set the
- interrupt level , DMA level , Ring Speed.\n
- Please refer to the Token ring Network 16/4 Adapter II
- Installation Guide for further details on switch
- settings."
-
- FUNCTION = "Token ring Network 16/4 Adapter II"
- TYPE = "NET,TOK"
- CONNECTION = "8-Pin RJ45 and 9-Pin D-Connector"
-
- SUBFUNCTION = "IO Base Address, RPL Setting"
- COMMENTS = "The factory default IO Base address location for the adapter
- is 86A0 and can vary from 86A0 to F6A0. The selected
- IO Base address must also be set in the Protocol.Ini file
- used by the software.
- The REMOTE PROGRAM LOAD function will be enabled via the
- card switch number 8."
-
- CHOICE = "86A0,RPL Disabled"
- LINK
- PORT = 086A0h-086AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 111
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
- CHOICE = "86A0,RPL Enabled"
- LINK
- PORT = 086A0h-086AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 111
- LINK
- INIT = SWITCH(1) LOC(1-3) 111
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
-
- MEMORY = 16K
- ADDRESS = 0C0000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "96A0,RPL Disabled"
- LINK
- PORT = 096A0h-096AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 011
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
- CHOICE = "96A0,RPL Enabled"
- LINK
- PORT = 096A0h-096AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 011
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 011
-
- MEMORY = 16K
- ADDRESS = 0C4000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "A6A0,RPL Disabled"
- LINK
- PORT = 0A6A0h-0A6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 101
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
- CHOICE = "A6A0,RPL Enabled"
- LINK
- PORT = 0A6A0h-0A6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 101
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 101
-
- MEMORY = 16K
- ADDRESS = 0C8000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "B6A0,RPL Disabled"
- LINK
- PORT = 0B6A0h-0B6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 001
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
-
- CHOICE = "B6A0,RPL Enabled"
- LINK
- PORT = 0B6A0h-0B6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 001
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 001
-
- MEMORY = 16K
- ADDRESS = 0CC000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "C6A0,RPL Disabled"
- LINK
- PORT = 0C6A0h-0C6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 110
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
- CHOICE = "C6A0,RPL Enabled"
- LINK
- PORT = 0C6A0h-0C6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 110
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 110
-
- MEMORY = 16K
- ADDRESS = 0D0000h
- WRITABLE = NO
- SIZE = BYTE
-
-
- CHOICE = "D6A0,RPL Disabled"
- LINK
- PORT = 0D6A0h-0D6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 010
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
-
- CHOICE = "D6A0,RPL Enabled"
- LINK
- PORT = 0D6A0h-0D6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 010
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 010
-
- MEMORY = 16K
- ADDRESS = 0D4000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "E6A0,RPL Disabled"
- LINK
- PORT = 0E6A0h-0E6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 100
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
-
-
- CHOICE = "E6A0,RPL Enabled"
- LINK
- PORT = 0E6A0h-0E6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 100
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
- LINK
- INIT = SWITCH(1) LOC(1-3) 100
-
- MEMORY = 16K
- ADDRESS = 0D8000h
- WRITABLE = NO
- SIZE = BYTE
-
- CHOICE = "F6A0,RPL Disabled"
- LINK
- PORT = 0F6A0h-0F6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 000
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 1
- CHOICE = "F6A0,RPL Enabled"
- LINK
- PORT = 0F6A0h-0F6AFh
- SHARE = NO
- SIZE = BYTE
- INIT = SWITCH(1) LOC(1-3) 000
- INIT = SWITCH(1) LOC(6-7) 11
- INIT = SWITCH(1) LOC(8) 0
-
- LINK
- INIT = SWITCH(1) LOC(1-3) 000
-
- MEMORY = 16K
- ADDRESS = 0DC000h
- WRITABLE = NO
- SIZE = BYTE
-
-
-
- SUBFUNCTION = "Interrupt Level"
- TYPE = "INT"
- COMMENTS = "The Token ring Network 16/4 Adapter II
- can operate on one of four interrupt levels: 9 ,10 , 10
- and 15. The factory default interrupt level is 9."
-
- CHOICE = "Interrupt 9"
- SUBTYPE = "9"
- LINK
- IRQ = 9
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(1) LOC(4 5) 11
- CHOICE = "Interrupt 10"
- SUBTYPE = "10"
- LINK
- IRQ = 10
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(1) LOC(4 5) 01
- CHOICE = "Interrupt 11"
- SUBTYPE = "11"
- LINK
- IRQ = 11
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(1) LOC(4 5) 10
- CHOICE = "Interrupt 15"
- SUBTYPE = "15"
- LINK
- IRQ = 15
- SHARE = NO
- TRIGGER = EDGE
- INIT = SWITCH(1) LOC(4 5) 00
-
-
-
-
- SUBFUNCTION = "DMA Level"
- COMMENTS = "\nUp to three Token ring Network 16/4 Adapter II
- may be installed within a single computer. When
- multiple adapters are being installed in a single computer,
- each adapter must be assigned to a different DMA channel.
- Select the appropriate function within the EISA
- Configuration Utility to display the switch setting(s)."
-
-
- CHOICE = "DMA 5"
- LINK
- DMA = 5
- SHARE = NO
- INIT = SWITCH(1) LOC(9 10) 11
- CHOICE = "DMA 6"
- LINK
- DMA = 6
- SHARE = NO
- INIT = SWITCH(1) LOC(9 10) 01
- CHOICE = "DMA 7"
- LINK
- DMA = 7
- SHARE = NO
- INIT = SWITCH(1) LOC(9 10) 00
-
- SUBFUNCTION = "Adapter Ring Speed"
- TYPE = "SPD"
- COMMENTS = "\nThe Token ring Network 16/4 Adapter II
- can operate at either 4 or 16 Mbps ring speed. The adapter
- ring speed MUST match the Token ring Network.\n
- Select the appropriate function within the EISA
- Configuration Utility to display the switch setting(s)."
-
- CHOICE = "4 Mbps"
- SUBTYPE = "4"
- FREE
- INIT = SWITCH(1) LOC(11) 1
- CHOICE = "16 Mbps"
- SUBTYPE = "16"
- FREE
- INIT = SWITCH(1) LOC(11) 0
-
- SUBFUNCTION = "Cable Type"
- TYPE = "SPD"
- COMMENTS = "\nThe Token ring Network 16/4 Adapter II
- can operate either using Shielded Twisted Pair cable or
- Unshielded Twisted Pair cable .\n
- Select the appropriate function within the EISA
- Configuration Utility to display the switch setting(s)."
-
- CHOICE = "STP Type"
- SUBTYPE = "STP"
- FREE
- INIT = SWITCH(1) LOC(12) 1
-
- CHOICE = "UTP Type"
- SUBTYPE = "UTP"
- FREE
- INIT = SWITCH(1) LOC(12) 0